HOMA-IR calculator
Estimate insulin resistance (HOMA-IR), beta-cell function (HOMA-%B) and QUICKI from a fasting glucose and fasting insulin taken at the same time.
Formulas
| Index | US units | SI units |
|---|---|---|
| HOMA-IR | glucose (mg/dL) × insulin (µU/mL) / 405 | glucose (mmol/L) × insulin / 22.5 |
| HOMA-%B | 360 × insulin / (glucose mg/dL − 63) | 20 × insulin / (glucose mmol/L − 3.5) |
| QUICKI | 1 / (log10 insulin + log10 glucose mg/dL) | Use glucose in mg/dL |
The model was calibrated so that a young, normal-weight reference population has HOMA-IR of 1 and HOMA-%B of 100%. Higher HOMA-IR means more insulin resistance. Published cut points for "insulin resistance" vary widely by population, assay and age, so no single number is universal; use the value to track change and discuss with your clinician.
HOMA-IR at common values
| Glucose \ insulin | 5 µU/mL | 10 | 15 | 20 | 30 |
|---|---|---|---|---|---|
| 80 mg/dL | 1.0 | 2.0 | 3.0 | 4.0 | 5.9 |
| 90 mg/dL | 1.1 | 2.2 | 3.3 | 4.4 | 6.7 |
| 100 mg/dL | 1.2 | 2.5 | 3.7 | 4.9 | 7.4 |
| 110 mg/dL | 1.4 | 2.7 | 4.1 | 5.4 | 8.1 |
| 126 mg/dL | 1.6 | 3.1 | 4.7 | 6.2 | 9.3 |
Worked example and limitations
Fasting glucose 100 mg/dL and fasting insulin 10 µU/mL give HOMA-IR = 100 × 10 / 405 = 2.47, HOMA-%B = 360 × 10 / (100 − 63) = 97%, and QUICKI = 1 / (log10 10 + log10 100) = 0.333.
- Insulin assays differ between labs, so values are best compared within the same lab.
- The simple formulas are the original 1985 HOMA1 model; the updated HOMA2 calculator from the University of Oxford gives somewhat different numbers.
- HOMA is not valid when glucose is very high, during acute illness, or with insulin treatment.
- One measurement varies; averaging two or three fasting samples improves reliability.
Frequently asked questions
Do I need to fast?
Yes. HOMA uses fasting values; both glucose and insulin should come from the same morning sample after 8 or more hours without food.
Can I use HOMA-IR if I take insulin?
No. Injected insulin makes the fasting insulin level meaningless for this model.
What is a normal HOMA-IR?
By design the reference value is about 1. Many studies label values above roughly 2 to 3 as insulin resistant, but thresholds differ between populations and labs.
Related tools
Sources
- Matthews DR, Hosker JP, Rudenski AS, et al. Homeostasis model assessment: insulin resistance and beta-cell function from fasting plasma glucose and insulin concentrations in man. Diabetologia. 1985;28(7):412-419.
- Katz A, Nambi SS, Mather K, et al. Quantitative insulin sensitivity check index: a simple, accurate method for assessing insulin sensitivity in humans. J Clin Endocrinol Metab. 2000;85(7):2402-2410.
This page is for education and does not replace advice from your doctor. Diagnosis of diabetes requires laboratory testing and, in most cases, a repeat test.