Blood sugar log average calculator
Paste or type your meter or CGM readings, separated by spaces, commas or new lines. The tool calculates the average, standard deviation, coefficient of variation, estimated A1C, GMI and the share of readings in each consensus range.
What the results mean
| Output | How it is calculated | Target |
|---|---|---|
| Mean glucose | Sum of readings / number of readings | Depends on goal; 154 mg/dL matches A1C 7% |
| Standard deviation (SD) | Sample SD of the readings | Lower is steadier |
| Coefficient of variation (CV) | SD / mean × 100 | ≤36% (international consensus) |
| Estimated A1C | (mean + 46.7) / 28.7 (ADAG) | <7% for many adults |
| GMI | 3.31 + 0.02392 × mean | Meant for 14+ days of CGM |
| Time in range | Share of readings 70–180 mg/dL | >70% (standard), >50% (older/high risk) |
Worked example
The ten sample readings above average 135 mg/dL with an SD of 28 mg/dL, a CV of 20.6%, an ADAG estimated A1C of 6.3% and a GMI of 6.5%. All ten are between 70 and 180 except 187, so 90% are in range.
Why fingerstick averages can mislead
Most people test before meals and at bedtime, when glucose is lowest, and rarely at the after-meal peak. A fingerstick average therefore often sits below the true 24-hour average, and the estimated A1C will read low. For an estimate close to the lab value, include some readings 1 to 2 hours after meals, or use at least 14 days of CGM data with 70% capture.
The coefficient of variation describes swings independent of the average. The 2019 international consensus on time in range set a CV of 36% or less as the target, because higher variability is linked with more hypoglycemia.
Frequently asked questions
How many readings do I need?
More is better. For a stable estimate, aim for at least 3 to 4 readings a day over 2 weeks, spread across fasting, pre-meal, after-meal and bedtime times.
Can I paste mmol/L values?
Yes. Choose mmol/L in the unit box; results are shown in both units.
Is the estimated A1C accurate?
It is an estimate. In ADAG, the 95% range of average glucose for a given A1C spanned roughly ±20%, so individual lab A1C values can differ.
Related tools
Sources
- Nathan DM, Kuenen J, Borg R, et al. Translating the A1C assay into estimated average glucose values (ADAG Study). Diabetes Care. 2008;31(8):1473-1478.
- Bergenstal RM, Beck RW, Close KL, et al. Glucose Management Indicator (GMI): a new term for estimating A1C from continuous glucose monitoring. Diabetes Care. 2018;41(11):2275-2280.
- Battelino T, Danne T, Bergenstal RM, et al. Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range. Diabetes Care. 2019;42(8):1593-1603.
This page is for education and does not replace advice from your doctor. Diagnosis of diabetes requires laboratory testing and, in most cases, a repeat test.